INSTALLER: Please leave this manual with the appliance owner for future reference.
NOT FOR USE WITH SOLID FUEL
200-0215
FEBRUARY 2005
EURO 25
EURO 25
-
-
1
1
Vented Gas Fireplace Insert
Heating Appliance
For use with natural gas or propane*
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Open windows
Do not touch any electrical switch; do not use any
phone in your building
Extinguish any open flame
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions
If you cannot reach your gas supplier, call the fire
department.
Do not use this appliance if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any part
of the control system and any control that has been
under water.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING: If the information in this manual
is not followed exactly, fire or explosion may
result causing property damage, personal
injury or loss of life.
7116 Beatty Drive
Mission, BC V2V 6B4
Canada
*Conversion Kit Required for Propane Use
USERS’ INSTALLATION
OPERATION AND
MAINTENANCE MANUAL
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - AINTENANCE MANUAL

INSTALLER: Please leave this manual with the appliance owner for future reference. NOT FOR USE WITH SOLID FUEL 200-0215 FEBRUARY 2005 EURO 25 EURO 25

Page 2

EURO 25 -1 10 MINIMUM MASONRY FIREPLACE DIMENSIONS 17” (432 mm) 25” (635 mm) 12” (305 mm)

Page 3 - INTRODUCTION

EURO 25 -1 11 INSTALLATION INSTRUCTIONS - Continued Flue connector straight-up vent Flue

Page 4

EURO 25 -1 12 PRECAUTIONS • This appliance must be installed by a qualified gas installe

Page 5 - TABLE OF CONTENTS

EURO 25 -1 13 GAS CONNECTIONS Have your gas supplier or a qualified gas fitter run a gas

Page 6 - SAFETY

EURO 25 -1 14 ATTACHMENT OF FIREPLACE SURROUND The surround has four hooks that clip onto

Page 7 - GENERAL INFORMATION

EURO 25 -1 15 GLASS DOOR WARNING: Glass door is fragile. Do not strike or abuse glass. D

Page 8

EURO 25 -1 16 WARNING : Do not place the embers directly on the burner ports. A fire, e

Page 9

EURO 25 -1 17 STEP 2 - Locate log #136 and place onto rear log support using locator pin

Page 10 - Flue connector

EURO 25 -1 18 STEP 4 - Locate log #140 and place onto centre of burner using the locator

Page 11

EURO 25 -1 19 STEP 6 - Locate log #135 and place onto rear log using the locator pins an

Page 13 - VENTING - Continued

EURO 25 -1 20 STEP 8 - Locate log #138 and place onto rear log using the locator pins an

Page 14

EURO 25 -1 21 OPERATION INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If

Page 15 - CENTER PANEL

EURO 25 -1 22 Set the thermostat, if present, to the lowest level. Set the flame adjustme

Page 16 - LOG PLACEMENT

EURO 25 -1 23 MAINTENANCE CAUTION : Maintenance should only be conducted on a cold applia

Page 17 - LOG PLACEMENT - Continued

EURO 25 -1 24 TROUBLESHOOTING SYMPTOM ACTION Pilot will not light after pressing the spa

Page 18

EURO 25 -1 25 TROUBLESHOOTING - Continued SYMPTOM ACTION The main burner does not turn o

Page 19

EURO 25 -1 26 SERVICING Before servicing, read the terms and conditions of the Archgard w

Page 20

EURO 25 -1 27 REPLACEMENT OF FAN • Disconnect the power to the appliance. • Remove the

Page 21 - OPERATION INSTRUCTIONS

EURO 25 -1 28 REPLACING MAJOR GAS COMPONENTS • Remove the glass door, log set and the bu

Page 22 - Continued

EURO 25 -1 29 APPENDIX A EURO 25-1 - INSTRUCTIONS FOR INSTALLATION INTO VENTED GAS FIREP

Page 23 - MAINTENANCE

Congratulations on purchasing the Archgard Euro-25 Gas Fireplace Insert Heater! The Euro-25 is one of the most advanced gas heating appliances on the

Page 24 - TROUBLESHOOTING

EURO 25 -1 30 HOST GAS FIREPLACE PREPARATION • The following procedures must be conducte

Page 25 - TROUBLESHOOTING - Continued

EURO 25 -1 31 VENTING OF THE EURO-25-1 INSIDE THE HOST GAS FIREPLACE A connector kit (BCV

Page 26 - SERVICING

EURO 25 -1 32 WARNING: This fireplace has been modified for use with the Archgard EURO-

Page 27 - SERVICING - Continued

EURO 25 -1 33 INSTALLATION INSTRUCTIONS INSTALLING THE EURO 25-1 GAS FIREPLACE INSERT HE

Page 28

EURO 25 -1 34 1. Unhook the screen rod at the center and remove screens or glass door. 2

Page 29 - APPENDIX A

EURO 25 -1 35 1. Remove the screens and rod or glass door. 2. Remove the bottom door tr

Page 30

EURO 25 -1 36 1. Remove the louvers and screens or glass door. 2. Remove the burner/san

Page 31

EURO 25 -1 37 1. Remove the screens or glass door. 2. Remove the burner assembly. (two

Page 32 - SAMPLE WARNING LABEL

EURO 25 -1 38 IMPORTANT INFORMATION * Please have the installer fill out the installation

Page 33 - INSTALLATION INSTRUCTIONS

This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an

Page 34

EURO 25 -1 4 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the

Page 35

EURO 25 -1 40 Parts can be ordered through your local dealer or distributor by giving ITE

Page 36

EURO 25 -1 41 NOTES

Page 37

POSTAGE FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED CUT ALONG LINE CUT ALONG LINE CUT ALONG LINE Model # : EURO 25 -1 Serial #:

Page 39

Archgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com

Page 40 - ITEM # and DESCRIPTION

TABLE OF CONTENTS Caution & Safety Information 5 General Information 6 Appliance Description and Dimensions 7 Installation Instructions 8 Oper

Page 41

EURO 25 -1 6 Due to high temperatures, the appliance should be located out of traffic an

Page 42 - ARCHGARD INDUSTRIES LTD

EURO 25 -1 7 GENERAL INFORMATION This appliance is tested and certified to the following

Page 43

EURO 25 -1 8 APPLIANCE DESCRIPTION & DIMENSIONS GAS VALVE CONVECTION FAN SPEED CONTRO

Page 44 - Archgard Industries Ltd

EURO 25 -1 9 Leveling leg INSTALLATION INSTRUCTIONS CLEARANCES TO COMBUSTIBLES Combustib